Skip to content
PM-12 · Approval
Approvals Client data · JSW ISPL Raipur: The client's own files (JSW ISPL Raipur): equipment, schedules, checklists, rosters and people are theirs. Done / missed is derived from the files by fixed rules, and nothing is written back. Preview mode: figures computed from client files. Demo data: Figures the client's files do not carry are filled with representative demo values, the same on every visit, so the screen reads complete. They are not the plant's records. Submitted work waits here for someone else to approve it, or send it back with a comment. Approved work goes on to SAP.
Plan Plant, checklist, frequency Assign Positions by shift roster Job card Auto-generated, executed 4 Approve Checked by another person 5 SAP Confirmed to SAP PM Filters Plant, department, area, status, frequency, dates Awaiting a decision (29) Submission time already fixed the compliance outcome (BR-PM12-1).
On this page3 all OK 1 with NOK readings
M1 Submitted 24 Oct 2026, 11:30
Furnace 3 Hydraulic Motor Ferro Alloy · MSL/FAD/E&I/FC3/HPM1
Ferro Alloy · Hydraulic Motors · PM & Clri · Done by L P Mishra (G shift) · approver P K Dwivedi
Open card Executed by L P Mishra Assistant Foreman · 24 Oct 2026, 12:43
Result All OK of 8 lines
Approver P K Dwivedi Engineer Comment (required to return) Approve Return for rework
Decisions are saved in this browser (demo).
Returned for rework (0) Back with the executor; a resubmission inside the cut-off keeps the original outcome (BR-PM12-2).
Nothing returned
No card has been sent back for rework.
Ferro Alloy · SETTLING TANK MOTORS
Ferro Alloy · SKIP HOIST
Ferro Alloy · SMOKE SEAL AIR BLOWER MOTORS
Ferro Alloy · TELFER MOTORS AND STARTERS
Ferro Alloy · ZIGGING MACHINE MOTORS
SMS-II E&I · Cranes
SMS-II E&I · Furnaces
SMS-II E&I · Plant-wide checks
SMS-II Mech · A Furnace
SMS-II Mech · Behind Pump house
SMS-II Mech · C & D Furnace
SMS-II Mech · C Furnace
SMS-II Mech · CCM
SMS-II Mech · CCM Pump house
SMS-II Mech · Cranes
SMS-II Mech · D Furnace
SMS-II Mech · E Furnace
SMS-II Mech · F Furnace
SMS-II Mech · F/C PUMP HOUSE
SMS-II Mech · FABRICATION YARD
SMS-II Mech · Furnace pump house
SMS-II Mech · Furnaces
SMS-II Mech · LDO Tank
SMS-II Mech · Near Overhead
SMS-II Mech · Near Set of 1
SMS-II Mech · Plant-wide checks
SMS-II Mech · Pump house
SMS-II Mech · Pump houses & cooling towers
SMS-II Mech · Reservoir(Booster pump)
SMS-II Mech · SetUP 1
Sponge DRI · Kiln 2
Sponge DRI · Kiln 2 & 3 & 4
Sponge DRI · Kiln 3
Sponge DRI · Kiln 3 & 4
Sponge DRI · Kiln 4
Status Any status open claimed submitted approved missed not due (shutdown)
Frequency Any frequency Every shift Daily Weekly Fortnightly Monthly
M1 Submitted 24 Oct 2026, 11:30
Furnace 3 Hydraulic Motor Standby Ferro Alloy · MSL/FAD/E&I/FC3/HPM2
Ferro Alloy · Hydraulic Motors · PM & Clri · Done by Durgesh Verma (G shift) · approver P K Dwivedi
Open card
Result 1 NOK of 8 lines
Approver P K Dwivedi Engineer You submitted this card, so you cannot approve it. A different supervisor has to.
15D Submitted 22 Oct 2026, 11:30
Kiln III & Cooler Sponge DRI · KILN-COOLER-03
Sponge DRI · Kiln 3 · Preventive maintenance per checklist: KILN & COOLER-03 · Done by Ajay Kashyap (G shift) · approver RaviNandan Yadav
Open card Executed by Ajay Kashyap Contractor technician · 22 Oct 2026, 16:32
Result All OK of 11 lines
Approver RaviNandan Yadav Preventive Maintenance Incharge (reports to Amit Singh) Comment (required to return) Approve Return for rework
Decisions are saved in this browser (demo).
15D Submitted 21 Oct 2026, 11:30
Kiln II & Cooler Sponge DRI · KILN-COOLER-02
Sponge DRI · Kiln 2 · Preventive maintenance per checklist: KILN & COOLER-02 · Done by Mr.S.K.KESHARWANI (G shift) · approver RaviNandan Yadav
Open card
Result All OK of 14 lines
Approver RaviNandan Yadav Preventive Maintenance Incharge (reports to Amit Singh) Comment (required to return) Approve Return for rework
Decisions are saved in this browser (demo).
Showing 26–29 of 29 cards · page 2 of 2